LOGR-S | SERIAL PORT SETUP
To view and modify the LOGR-S Serial Port settings:
1. Navigate to Sensors > Serial Ports Setup
2. Confirm port settings for COM-A and COM-B match modbus settings for desired sensors
Default settings for both COM-A and COM-B:
• Baud Rate - 19200
• Stop Bits - 1
• Data Bits - 8
• Parity - Even
3. Select Save
4. Listen for an audible alert (two beeps) from the LOGR-S confirming Serial Port Setup has been saved