- Home
- Products
- Solar Systems
- Soiling Performance Kit
Soiling Performance Kit
Measure the impact of soiling on PV module performance with this IEC-compliant Soiling Performance Kit.
Details
The NRG Soiling Performance Kit is a complete solution designed to accurately quantify the impact of soiling on solar project performance. Designed for reliability in the most demanding conditions, the Soiling Performance Kit helps solar energy professionals to assess and manage soiling losses effectively and with confidence. Its easy deployment enables efficient and accurate measurements from distributed stations, making it valuable for larger PV plants, where soiling rates can vary across different areas of the site.
This comprehensive solution pairs the NRG Soiling Measurement Kit – compatible with both thin-film and crystalline solar modules and including a Pulsed Soiling Module (PSM1), NRG PVT1 PV Temperature Sensors, and a solar maintenance button – with the LOGR | Solar Data Logger, the NRG R2 Class A Pyranometer, and a dedicated power supply for continuous AC power. Together, these components provide a rich dataset for effectively monitoring soiling impact and overall plant performance.
Key measurements recorded by the LOGR | Solar Data Logger include short-circuit current, open circuit voltage, back-of-module temperature, effective irradiance, soiling ratio, and daily soiling-loss index. These measurements are accessible on-site site via Modbus or remotely through NRG Cloud, enabling seamless data retrieval and analysis. With NRG’s bankable measurements, solar professionals can ensure precise performance monitoring and optimize plant operations with confidence.
The Soiling Performance Kit is designed to be deployed alongside the NRG Flare SRM System but can also be installed as a standalone solution, making it a flexible choice for any project.
Benefits
- Ability to support distributed measurements makes it easy to collect soiling data from different parts of your solar site
- Compatibility with thin-film or crystalline modules ensures accurate representation of soiling losses on site
- High performance, IEC61724-1:2021 Method 2-compliant soiling solution
- Flexible configuration options accommodate post-construction mounting on a wide range of PV panels
- NRG’s R2 Class A Pyranometer provides high-accuracy effective irradiance reference input
- SCADA or remote access via NRG Cloud to daily soiling ratio and soiling loss monitoring for optimal flexibility
- Robust data storage capabilities and standardized Modbus map
- Additional inputs available on LOGR | Solar Data Logger for supplementary measurements
- Integrates seamlessly with NRG Flare Systems
Recommended Items
In the Box
- Soiling Measurement Kit (PSM1)
- LOGR | Solar Data Logger
- NRG R2 Pyranometer (Digital)
- NRG PVT1 PV Temperature Sensors (2x)
- Power Supply
- Mounting
- Cabling
Specifications Print Specs
CRYSTALLINE, ROUND TT (#19950) | CRYSTALLINE, SQUARE TORQUE TUBE (#19951) | THIN FILM, ROUND TORQUE TUBE (#19952) | THIN FILM, SQUARE TORQUE TUBE (#19953) | |
---|---|---|---|---|
Description | ||||
Instrument type |
LOGR | Solar: High utility data logger, real-time sensor interface NRG R2-D Pyranometer: Thermopile solar radiation sensor, ISO 9060:2018 Class A (Secondary Standard) Soiling Measurement Kit (SMK) Crystalline and Thin Film
|
LOGR | Solar: High utility data logger, real-time sensor interface NRG R2-D Pyranometer: Thermopile solar radiation sensor, ISO 9060:2018 Class A (Secondary Standard) Soiling Measurement Kit (SMK) Crystalline and Thin Film
|
LOGR | Solar: High utility data logger, real-time sensor interface NRG R2-D Pyranometer: Thermopile solar radiation sensor, ISO 9060:2018 Class A (Secondary Standard) Soiling Measurement Kit (SMK) Crystalline and Thin Film
|
LOGR | Solar: High utility data logger, real-time sensor interface NRG R2-D Pyranometer: Thermopile solar radiation sensor, ISO 9060:2018 Class A (Secondary Standard) Soiling Measurement Kit (SMK) Crystalline and Thin Film
|
System Applications |
Solar Resource Monitoring Soiling Loss Measurement Soiling Performance Measurement, with soiling ratio values derived from measured PV module short
circuit current (Isc) and back-of-module temperature data
|
Solar Resource Monitoring Soiling Loss Measurement Soiling Performance Measurement, with soiling ratio values derived from measured PV module short
circuit current (Isc) and back-of-module temperature data
|
Solar Resource Monitoring Soiling Loss Measurement Soiling Performance Measurement, with soiling ratio values derived from measured PV module short
circuit current (Isc) and back-of-module temperature data
|
Solar Resource Monitoring Soiling Loss Measurement Soiling Performance Measurement, with soiling ratio values derived from measured PV module short
circuit current (Isc) and back-of-module temperature data
|
Compliance | IEC 61724-1:2021 | IEC 61724-1:2021 | IEC 61724-1:2021 | IEC 61724-1:2021 |
Data Outputs |
Short-circuit current Back-of-module (BOM) temperature Effective irradiance Soiling ratio Daily soiling loss index
|
Short-circuit current Back-of-module (BOM) temperature Effective irradiance Soiling ratio Daily soiling loss index
|
Short-circuit current Back-of-module (BOM) temperature Effective irradiance Soiling ratio Daily soiling loss index
|
Short-circuit current Back-of-module (BOM) temperature Effective irradiance Soiling ratio Daily soiling loss index
|
Data Collection | ||||
Averaging interval | 1 minute (IEC 61724-1 compliant) | 1 minute (IEC 61724-1 compliant) | 1 minute (IEC 61724-1 compliant) | 1 minute (IEC 61724-1 compliant) |
Data Storage | 90 days at 1 second intervals, or 365 days at 1-minute intervals | 90 days at 1 second intervals, or 365 days at 1-minute intervals | 90 days at 1 second intervals, or 365 days at 1-minute intervals | 90 days at 1 second intervals, or 365 days at 1-minute intervals |
Data Storage Interval | 1 second and 1 minute intervals available | 1 second and 1 minute intervals available | 1 second and 1 minute intervals available | 1 second and 1 minute intervals available |
Communications |
Real-time data delivery via Modbus registers (TCP via Ethernet or RTU via RS-485) Scheduled delivery of historical data via FTP On-demand transfer of historical data via internal web server to FTP
|
Real-time data delivery via Modbus registers (TCP via Ethernet or RTU via RS-485) Scheduled delivery of historical data via FTP On-demand transfer of historical data via internal web server to FTP
|
Real-time data delivery via Modbus registers (TCP via Ethernet or RTU via RS-485) Scheduled delivery of historical data via FTP On-demand transfer of historical data via internal web server to FTP
|
Real-time data delivery via Modbus registers (TCP via Ethernet or RTU via RS-485) Scheduled delivery of historical data via FTP On-demand transfer of historical data via internal web server to FTP
|
Inputs | ||||
Input Voltage | 110 to 240 VAC | 110 to 240 VAC | 110 to 240 VAC | 110 to 240 VAC |
Nominal Current | 0.2 Amps | 0.2 Amps | 0.2 Amps | 0.2 Amps |
Maximum Current | 1.2 A @ 115 VAC | 1.2 A @ 115 VAC | 1.2 A @ 115 VAC | 1.2 A @ 115 VAC |
Outputs | ||||
Effective Irradiance Range | 0 to 1500 W/m2 | 0 to 1500 W/m2 | 0 to 1500 W/m2 | 0 to 1500 W/m2 |
Daily Soiling Ratio Range | 0 to 1, daily average | 0 to 1, daily average | 0 to 1, daily average | 0 to 1, daily average |
PV Modules | ||||
Maximum Voltage | 450 VDC | 450 VDC | 450 VDC | 450 VDC |
Maximum Current |
Crystalline: 30 Amps Thin Film: 5 Amps
|
Crystalline: 30 Amps Thin Film: 5 Amps
|
Crystalline: 30 Amps Thin Film: 5 Amps
|
Crystalline: 30 Amps Thin Film: 5 Amps
|
Environmental Specifications | ||||
Operating Temperature Range | -40 °C to 65 °C (-40 °F to 149 °F) | -40 °C to 65 °C (-40 °F to 149 °F) | -40 °C to 65 °C (-40 °F to 149 °F) | -40 °C to 65 °C (-40 °F to 149 °F) |
Operating Humidity Range | 0 to 100% (non-condensing) | 0 to 100% (non-condensing) | 0 to 100% (non-condensing) | 0 to 100% (non-condensing) |
Materials | ||||
Enclosure | IP68 | IP68 | IP68 | IP68 |
Enclosure Dimensions |
Height - 17.43” Width - 15.43” Depth - 7.34”
|
Height - 17.43” Width - 15.43” Depth - 7.34”
|
Height - 17.43” Width - 15.43” Depth - 7.34”
|
Height - 17.43” Width - 15.43” Depth - 7.34”
|
Hardware Specifications | ||||
Warranty | Two-year warranty | Two-year warranty | Two-year warranty | Two-year warranty |
- Instrument type
-
LOGR | Solar: High utility data logger, real-time sensor interfaceNRG R2-D Pyranometer: Thermopile solar radiation sensor, ISO 9060:2018 Class A (Secondary Standard)Soiling Measurement Kit (SMK) Crystalline and Thin Film
- System Applications
-
Solar Resource MonitoringSoiling Loss MeasurementSoiling Performance Measurement, with soiling ratio values derived from measured PV module short circuit current (Isc) and back-of-module temperature data
- Compliance
- IEC 61724-1:2021
- Data Outputs
-
Short-circuit currentBack-of-module (BOM) temperatureEffective irradianceSoiling ratioDaily soiling loss index
- Averaging interval
- 1 minute (IEC 61724-1 compliant)
- Data Storage
- 90 days at 1 second intervals, or 365 days at 1-minute intervals
- Data Storage Interval
- 1 second and 1 minute intervals available
- Communications
-
Real-time data delivery via Modbus registers (TCP via Ethernet or RTU via RS-485)Scheduled delivery of historical data via FTPOn-demand transfer of historical data via internal web server to FTP
- Input Voltage
- 110 to 240 VAC
- Nominal Current
- 0.2 Amps
- Maximum Current
- 1.2 A @ 115 VAC
- Effective Irradiance Range
- 0 to 1500 W/m2
- Daily Soiling Ratio Range
- 0 to 1, daily average
- Maximum Voltage
- 450 VDC
- Maximum Current
-
Crystalline: 30 AmpsThin Film: 5 Amps
- Operating Temperature Range
- -40 °C to 65 °C (-40 °F to 149 °F)
- Operating Humidity Range
- 0 to 100% (non-condensing)
- Enclosure
- IP68
- Enclosure Dimensions
-
Height - 17.43”Width - 15.43”Depth - 7.34”
- Warranty
- Two-year warranty
- Instrument type
-
LOGR | Solar: High utility data logger, real-time sensor interfaceNRG R2-D Pyranometer: Thermopile solar radiation sensor, ISO 9060:2018 Class A (Secondary Standard)Soiling Measurement Kit (SMK) Crystalline and Thin Film
- System Applications
-
Solar Resource MonitoringSoiling Loss MeasurementSoiling Performance Measurement, with soiling ratio values derived from measured PV module short circuit current (Isc) and back-of-module temperature data
- Compliance
- IEC 61724-1:2021
- Data Outputs
-
Short-circuit currentBack-of-module (BOM) temperatureEffective irradianceSoiling ratioDaily soiling loss index
- Averaging interval
- 1 minute (IEC 61724-1 compliant)
- Data Storage
- 90 days at 1 second intervals, or 365 days at 1-minute intervals
- Data Storage Interval
- 1 second and 1 minute intervals available
- Communications
-
Real-time data delivery via Modbus registers (TCP via Ethernet or RTU via RS-485)Scheduled delivery of historical data via FTPOn-demand transfer of historical data via internal web server to FTP
- Input Voltage
- 110 to 240 VAC
- Nominal Current
- 0.2 Amps
- Maximum Current
- 1.2 A @ 115 VAC
- Effective Irradiance Range
- 0 to 1500 W/m2
- Daily Soiling Ratio Range
- 0 to 1, daily average
- Maximum Voltage
- 450 VDC
- Maximum Current
-
Crystalline: 30 AmpsThin Film: 5 Amps
- Operating Temperature Range
- -40 °C to 65 °C (-40 °F to 149 °F)
- Operating Humidity Range
- 0 to 100% (non-condensing)
- Enclosure
- IP68
- Enclosure Dimensions
-
Height - 17.43”Width - 15.43”Depth - 7.34”
- Warranty
- Two-year warranty
- Instrument type
-
LOGR | Solar: High utility data logger, real-time sensor interfaceNRG R2-D Pyranometer: Thermopile solar radiation sensor, ISO 9060:2018 Class A (Secondary Standard)Soiling Measurement Kit (SMK) Crystalline and Thin Film
- System Applications
-
Solar Resource MonitoringSoiling Loss MeasurementSoiling Performance Measurement, with soiling ratio values derived from measured PV module short circuit current (Isc) and back-of-module temperature data
- Compliance
- IEC 61724-1:2021
- Data Outputs
-
Short-circuit currentBack-of-module (BOM) temperatureEffective irradianceSoiling ratioDaily soiling loss index
- Averaging interval
- 1 minute (IEC 61724-1 compliant)
- Data Storage
- 90 days at 1 second intervals, or 365 days at 1-minute intervals
- Data Storage Interval
- 1 second and 1 minute intervals available
- Communications
-
Real-time data delivery via Modbus registers (TCP via Ethernet or RTU via RS-485)Scheduled delivery of historical data via FTPOn-demand transfer of historical data via internal web server to FTP
- Input Voltage
- 110 to 240 VAC
- Nominal Current
- 0.2 Amps
- Maximum Current
- 1.2 A @ 115 VAC
- Effective Irradiance Range
- 0 to 1500 W/m2
- Daily Soiling Ratio Range
- 0 to 1, daily average
- Maximum Voltage
- 450 VDC
- Maximum Current
-
Crystalline: 30 AmpsThin Film: 5 Amps
- Operating Temperature Range
- -40 °C to 65 °C (-40 °F to 149 °F)
- Operating Humidity Range
- 0 to 100% (non-condensing)
- Enclosure
- IP68
- Enclosure Dimensions
-
Height - 17.43”Width - 15.43”Depth - 7.34”
- Warranty
- Two-year warranty
- Instrument type
-
LOGR | Solar: High utility data logger, real-time sensor interfaceNRG R2-D Pyranometer: Thermopile solar radiation sensor, ISO 9060:2018 Class A (Secondary Standard)Soiling Measurement Kit (SMK) Crystalline and Thin Film
- System Applications
-
Solar Resource MonitoringSoiling Loss MeasurementSoiling Performance Measurement, with soiling ratio values derived from measured PV module short circuit current (Isc) and back-of-module temperature data
- Compliance
- IEC 61724-1:2021
- Data Outputs
-
Short-circuit currentBack-of-module (BOM) temperatureEffective irradianceSoiling ratioDaily soiling loss index
- Averaging interval
- 1 minute (IEC 61724-1 compliant)
- Data Storage
- 90 days at 1 second intervals, or 365 days at 1-minute intervals
- Data Storage Interval
- 1 second and 1 minute intervals available
- Communications
-
Real-time data delivery via Modbus registers (TCP via Ethernet or RTU via RS-485)Scheduled delivery of historical data via FTPOn-demand transfer of historical data via internal web server to FTP
- Input Voltage
- 110 to 240 VAC
- Nominal Current
- 0.2 Amps
- Maximum Current
- 1.2 A @ 115 VAC
- Effective Irradiance Range
- 0 to 1500 W/m2
- Daily Soiling Ratio Range
- 0 to 1, daily average
- Maximum Voltage
- 450 VDC
- Maximum Current
-
Crystalline: 30 AmpsThin Film: 5 Amps
- Operating Temperature Range
- -40 °C to 65 °C (-40 °F to 149 °F)
- Operating Humidity Range
- 0 to 100% (non-condensing)
- Enclosure
- IP68
- Enclosure Dimensions
-
Height - 17.43”Width - 15.43”Depth - 7.34”
- Warranty
- Two-year warranty
Product Support
Customer Service
+1 802-482-2255