Achieve IEC Class A measurements using our high-accuracy PV temperature sensor.
Details
Because temperature has a significant impact on the performance of operational PV solar systems, PV module temperature is one of the most critical measurements to monitor and analyze.
Purpose-built to withstand the elements and accurately sense PV module temperature, our 0.2 C interchangeable 10K NTC Thermistor sensor ensures Class A measurements per IEC-61724-1:2017. The PVT1’s 4-wire cable configuration delivers accurate measurement regardless of cable length when used with our SymphoniePRO Data Logger and enables flexible positioning on PV arrays.
Each sensor comes with double-sided adhesive on its compact housing as well as a specially designed adhesive system to secure both sensor and cable in place for easy and repeatable installation as well as long-term performance.
Specifications Print Specs
3m (#9421) | 10m (#9422) | 20m (#9423) | 50m (#9424) | 100M (#9426) | |
---|---|---|---|---|---|
Description | |||||
Sensor type | 10 kΩ NTC thermistor | 10 kΩ NTC thermistor | 10 kΩ NTC thermistor | 10 kΩ NTC thermistor | 10 kΩ NTC thermistor |
Applications |
|
|
|
|
|
Sensor range | -55 °C to 150 °C (-67 °F to 302 °F) | -55 °C to 150 °C (-67 °F to 302 °F) | -55 °C to 150 °C (-67 °F to 302 °F) | -55 °C to 150 °C (-67 °F to 302 °F) | -55 °C to 150 °C (-67 °F to 302 °F) |
Instrument compatibility | NRG SymphoniePRO Data Logger | NRG SymphoniePRO Data Logger | NRG SymphoniePRO Data Logger | NRG SymphoniePRO Data Logger | NRG SymphoniePRO Data Logger |
Output signal | |||||
Transfer function |
Steinhart-Hart Coefficients:
|
Steinhart-Hart Coefficients:
|
Steinhart-Hart Coefficients:
|
Steinhart-Hart Coefficients:
|
Steinhart-Hart Coefficients:
|
Accuracy | ± 0.2 °C from 0 to 70 °C (±0.36 °F from 32 to 158 °F) | ± 0.2 °C from 0 to 70 °C (±0.36 °F from 32 to 158 °F) | ± 0.2 °C from 0 to 70 °C (±0.36 °F from 32 to 158 °F) | ± 0.2 °C from 0 to 70 °C (±0.36 °F from 32 to 158 °F) | ± 0.2 °C from 0 to 70 °C (±0.36 °F from 32 to 158 °F) |
Power requirements | |||||
Supply current | 15 μA maximum (supplied by logger) | 15 μA maximum (supplied by logger) | 15 μA maximum (supplied by logger) | 15 μA maximum (supplied by logger) | 15 μA maximum (supplied by logger) |
Installation | |||||
Mounting | Adhere to back of PV module (adhesive tape included) | Adhere to back of PV module (adhesive tape included) | Adhere to back of PV module (adhesive tape included) | Adhere to back of PV module (adhesive tape included) | Adhere to back of PV module (adhesive tape included) |
Environmental | |||||
Operating temperature range | -40 °C to 105 °C (-40 °F to 221 °F) | -40 °C to 105 °C (-40 °F to 221 °F) | -40 °C to 105 °C (-40 °F to 221 °F) | -40 °C to 105 °C (-40 °F to 221 °F) | -40 °C to 105 °C (-40 °F to 221 °F) |
Operating humidity range | 0 to 100% RH | 0 to 100% RH | 0 to 100% RH | 0 to 100% RH | 0 to 100% RH |
Physical | |||||
Connections |
Wire leads:
|
Wire leads:
|
Wire leads:
|
Wire leads:
|
Wire leads:
|
Cable length | 3.0 m (9.8 ft) | 10.0 m (33 ft) | 20.0 m (66 ft) | 50.0 m (164 ft) | 100.0 m (328 ft) |
Weight | 46.7 g (0.10 lbs) | 156.9 g (0.35 lbs) | 313.8 g (0.69 lbs) | 790 g (1.74 lbs) | 1637 g (3.61 lbs) |
Dimensions | Probe only: 25 mm (1") long x 12.7 mm (0.5") width x 6.2 mm (.25") thick | Probe only: 25 mm (1") long x 12.7 mm (0.5") width x 6.2 mm (.25") thick | Probe only: 25 mm (1") long x 12.7 mm (0.5") width x 6.2 mm (.25") thick | Probe only: 25 mm (1") long x 12.7 mm (0.5") width x 6.2 mm (.25") thick | Probe only: 25 mm (1") long x 12.7 mm (0.5") width x 6.2 mm (.25") thick |
Materials | |||||
Cable | 4 conductor 28 AWG, with foil shield and drain wire, PUR jacket | 4 conductor 28 AWG, with foil shield and drain wire, PUR jacket | 4 conductor 28 AWG, with foil shield and drain wire, PUR jacket | 4 conductor 28 AWG, with foil shield and drain wire, PUR jacket | 4 conductor 28 AWG, with foil shield and drain wire, PUR jacket |
Probe | Aluminum, epoxy filled | Aluminum, epoxy filled | Aluminum, epoxy filled | Aluminum, epoxy filled | Aluminum, epoxy filled |
- Sensor type
- 10 kΩ NTC thermistor
- Applications
-
- Solar resource monitoring
- Surface temperature measurement
- Solar resource monitoring
- Sensor range
- -55 °C to 150 °C (-67 °F to 302 °F)
- Instrument compatibility
- NRG SymphoniePRO Data Logger
- Transfer function
-
Steinhart-Hart Coefficients:
- A = 0.001032
- B = 0.0002387
- C = 0.000000158
Beta Value: 3694 K
Beta Value Tolerance: 0.80%
- Accuracy
- ± 0.2 °C from 0 to 70 °C (±0.36 °F from 32 to 158 °F)
- Supply current
- 15 μA maximum (supplied by logger)
- Mounting
- Adhere to back of PV module (adhesive tape included)
- Operating temperature range
- -40 °C to 105 °C (-40 °F to 221 °F)
- Operating humidity range
- 0 to 100% RH
- Connections
-
Wire leads:
- Excitation (red wire)
- Ground (black wire)
- Signal + (white wire)
- Signal - (green wire)
- Drain wire for earth ground
- Cable length
- 3.0 m (9.8 ft)
- Weight
- 46.7 g (0.10 lbs)
- Dimensions
- Probe only: 25 mm (1") long x 12.7 mm (0.5") width x 6.2 mm (.25") thick
- Cable
- 4 conductor 28 AWG, with foil shield and drain wire, PUR jacket
- Probe
- Aluminum, epoxy filled
- Sensor type
- 10 kΩ NTC thermistor
- Applications
-
- Solar resource monitoring
- Surface temperature measurement
- Solar resource monitoring
- Sensor range
- -55 °C to 150 °C (-67 °F to 302 °F)
- Instrument compatibility
- NRG SymphoniePRO Data Logger
- Transfer function
-
Steinhart-Hart Coefficients:
- A = 0.001032
- B = 0.0002387
- C = 0.000000158
Beta Value: 3694 K
Beta Value Tolerance: 0.80%
- Accuracy
- ± 0.2 °C from 0 to 70 °C (±0.36 °F from 32 to 158 °F)
- Supply current
- 15 μA maximum (supplied by logger)
- Mounting
- Adhere to back of PV module (adhesive tape included)
- Operating temperature range
- -40 °C to 105 °C (-40 °F to 221 °F)
- Operating humidity range
- 0 to 100% RH
- Connections
-
Wire leads:
- Excitation (red wire)
- Ground (black wire)
- Signal + (white wire)
- Signal - (green wire)
- Drain wire for earth ground
- Cable length
- 10.0 m (33 ft)
- Weight
- 156.9 g (0.35 lbs)
- Dimensions
- Probe only: 25 mm (1") long x 12.7 mm (0.5") width x 6.2 mm (.25") thick
- Cable
- 4 conductor 28 AWG, with foil shield and drain wire, PUR jacket
- Probe
- Aluminum, epoxy filled
- Sensor type
- 10 kΩ NTC thermistor
- Applications
-
- Solar resource monitoring
- Surface temperature measurement
- Solar resource monitoring
- Sensor range
- -55 °C to 150 °C (-67 °F to 302 °F)
- Instrument compatibility
- NRG SymphoniePRO Data Logger
- Transfer function
-
Steinhart-Hart Coefficients:
- A = 0.001032
- B = 0.0002387
- C = 0.000000158
Beta Value: 3694 K
Beta Value Tolerance: 0.80%
- Accuracy
- ± 0.2 °C from 0 to 70 °C (±0.36 °F from 32 to 158 °F)
- Supply current
- 15 μA maximum (supplied by logger)
- Mounting
- Adhere to back of PV module (adhesive tape included)
- Operating temperature range
- -40 °C to 105 °C (-40 °F to 221 °F)
- Operating humidity range
- 0 to 100% RH
- Connections
-
Wire leads:
- Excitation (red wire)
- Ground (black wire)
- Signal + (white wire)
- Signal - (green wire)
- Drain wire for earth ground
- Cable length
- 20.0 m (66 ft)
- Weight
- 313.8 g (0.69 lbs)
- Dimensions
- Probe only: 25 mm (1") long x 12.7 mm (0.5") width x 6.2 mm (.25") thick
- Cable
- 4 conductor 28 AWG, with foil shield and drain wire, PUR jacket
- Probe
- Aluminum, epoxy filled
- Sensor type
- 10 kΩ NTC thermistor
- Applications
-
- Solar resource monitoring
- Surface temperature measurement
- Solar resource monitoring
- Sensor range
- -55 °C to 150 °C (-67 °F to 302 °F)
- Instrument compatibility
- NRG SymphoniePRO Data Logger
- Transfer function
-
Steinhart-Hart Coefficients:
- A = 0.001032
- B = 0.0002387
- C = 0.000000158
Beta Value: 3694 K
Beta Value Tolerance: 0.80%
- Accuracy
- ± 0.2 °C from 0 to 70 °C (±0.36 °F from 32 to 158 °F)
- Supply current
- 15 μA maximum (supplied by logger)
- Mounting
- Adhere to back of PV module (adhesive tape included)
- Operating temperature range
- -40 °C to 105 °C (-40 °F to 221 °F)
- Operating humidity range
- 0 to 100% RH
- Connections
-
Wire leads:
- Excitation (red wire)
- Ground (black wire)
- Signal + (white wire)
- Signal - (green wire)
- Drain wire for earth ground
- Cable length
- 50.0 m (164 ft)
- Weight
- 790 g (1.74 lbs)
- Dimensions
- Probe only: 25 mm (1") long x 12.7 mm (0.5") width x 6.2 mm (.25") thick
- Cable
- 4 conductor 28 AWG, with foil shield and drain wire, PUR jacket
- Probe
- Aluminum, epoxy filled
- Sensor type
- 10 kΩ NTC thermistor
- Applications
-
- Solar resource monitoring
- Surface temperature measurement
- Solar resource monitoring
- Sensor range
- -55 °C to 150 °C (-67 °F to 302 °F)
- Instrument compatibility
- NRG SymphoniePRO Data Logger
- Transfer function
-
Steinhart-Hart Coefficients:
- A = 0.001032
- B = 0.0002387
- C = 0.000000158
Beta Value: 3694 K
Beta Value Tolerance: 0.80%
- Accuracy
- ± 0.2 °C from 0 to 70 °C (±0.36 °F from 32 to 158 °F)
- Supply current
- 15 μA maximum (supplied by logger)
- Mounting
- Adhere to back of PV module (adhesive tape included)
- Operating temperature range
- -40 °C to 105 °C (-40 °F to 221 °F)
- Operating humidity range
- 0 to 100% RH
- Connections
-
Wire leads:
- Excitation (red wire)
- Ground (black wire)
- Signal + (white wire)
- Signal - (green wire)
- Drain wire for earth ground
- Cable length
- 100.0 m (328 ft)
- Weight
- 1637 g (3.61 lbs)
- Dimensions
- Probe only: 25 mm (1") long x 12.7 mm (0.5") width x 6.2 mm (.25") thick
- Cable
- 4 conductor 28 AWG, with foil shield and drain wire, PUR jacket
- Probe
- Aluminum, epoxy filled