Connect sensors and protect your data logger from electrostatic discharge with an NRG wiring panel.
Details
Our wiring panels are designed with the field user in mind. Dedicated terminals for every sensor wire and clear labeling help ensure mistake-free wiring. These input protection devices are required to connect digital and analog sensors to Symphonie® series data loggers. Each wiring panel features channel-by-channel surge protection to shield sensitive data logger circuitry from electrostatic discharge (ESD).
In the event of a lightning strike, the wiring panel will divert the energy to Earth Ground, protecting the data logger from damage. Severe ESD events may require replacement of the wiring panel to restore normal data logging operations.
We recommend carrying a spare wiring panel when performing site visits.
Specifications Print Specs
SYMPHONIEPRO, 16-CHANNEL (#11178) | SYMPHONIEPRO, 26-CHANNEL (#9294) | |
---|---|---|
Description | ||
Instrument type | 16 channel wiring panel for SymphoniePRO Data Logger | 26 channel wiring panel for SymphoniePRO Data Logger |
Applications | Wind and solar resource assessment, power performance monitoring, and forecasting | Wind and solar resource assessment, power performance monitoring, and forecasting |
Instrument compatibility | SymphoniePRO data logger | SymphoniePRO data logger |
Data Collection | ||
Channel Capacity |
|
|
Counter Channels Sensor Compatibility |
Compatable with a wide array of industry-standard anemometers including:
|
Compatable with a wide array of industry-standard anemometers including:
|
Analog Channels Sensor Compatibility |
Compatible with a wide array of sensors including:
|
Compatible with a wide array of sensors including:
|
Connections | ||
Sensor wiring |
|
|
Expansion slots | Three (3) Analog channels configurable with P-SCM signal conditioning modules |
Seven (7) signal conditioning module slots accept analog P-SCMs
|
Installation | ||
Mounting | Wiring panel mounts directly to Logger with two screws | Wiring panel mounts separately to shelter box back plate with four (4) Phillips 10-32 x 0.5 in. screws |
Tools required |
|
|
Environmental | ||
Operating temperature range | -40 °C to 65 °C (-40 °F to 149 °F) | -40 °C to 65 °C (-40 °F to 149 °F) |
Operating humidity range |
|
0 to 100% RH non-condensing |
Physical | ||
Weight | .15 Kg (.33 lb) |
|
Dimensions | 11.4 cm x 7.6 cm x 5 cm (4.5 in. x 3 in. x 2 in.) |
|
Materials | ||
Wiring panel |
|
Formed aluminum enclosure, zinc-plated screws and terminals |
- Instrument type
- 16 channel wiring panel for SymphoniePRO Data Logger
- Applications
- Wind and solar resource assessment, power performance monitoring, and forecasting
- Instrument compatibility
- SymphoniePRO data logger
- Channel Capacity
-
- Eight (8) counter channels
- Eight (8) analog channels: Five (5) built-in, Three (3) configurable with signal conditioning modules (P-SCMs)
- Counter Channels Sensor Compatibility
-
Compatable with a wide array of industry-standard anemometers including:
- Opto anemometers
- Reed switch anemometers
- Other frequency signals up to 2,500 Hz
- Analog Channels Sensor Compatibility
-
Compatible with a wide array of sensors including:
- NRG standard analog sensors (200P Wind Direction Vane, 110S Temperature, BP20 Barometric Pressure, RH5X Relative Humidity, etc)
- Industry-standard pyranometers
- Three (3) Built-in channels: 0 to 5 V Analog; 2.5 or 5 V excitation; no P-SCMs required
- Two (2) Built-in channels: 0 to 5 V Analog; 5 or 12 V excitation; no P-SCMs required
- Three (3) P-SCM Channels: signal range dependent on individual P-SCM card
- Sensor wiring
-
- Sensors connect to wiring panel
- Field wiring panel plugs directly into logger
- Wiring panel ground stud connects to earth ground with included ground cable
- Expansion slots
- Three (3) Analog channels configurable with P-SCM signal conditioning modules
- Mounting
- Wiring panel mounts directly to Logger with two screws
- Tools required
-
- Screwdriver for wiring panel input terminals (included)
- 8mm (5/16 in.) wrench or nut driver for mounting screws and logger ground lug
- Operating temperature range
- -40 °C to 65 °C (-40 °F to 149 °F)
- Operating humidity range
-
- 0 to 100% relative humidity non-condensing
- IP65 ingress protection with proper installation in Symphonie shelter box enclosure
- Weight
- .15 Kg (.33 lb)
- Dimensions
- 11.4 cm x 7.6 cm x 5 cm (4.5 in. x 3 in. x 2 in.)
- Wiring panel
-
- Black ABS enclosure
- Zinc-plated screws and terminals
- Instrument type
- 26 channel wiring panel for SymphoniePRO Data Logger
- Applications
- Wind and solar resource assessment, power performance monitoring, and forecasting
- Instrument compatibility
- SymphoniePRO data logger
- Channel Capacity
-
- Twelve (12) counter channels
- Fourteen (14) analog channels: Seven (7) built-in, Seven (7) configurable with signal conditioning modules (P-SCMs)
- Two (2) RS-485 communication channels, each full or half duplex with support for up to 6 devices
- Counter Channels Sensor Compatibility
-
Compatable with a wide array of industry-standard anemometers including:
- Opto anemometers
- Reed switch anemometers
- Other frequency signals up to 2,500 Hz
- Analog Channels Sensor Compatibility
-
Compatible with a wide array of sensors including:
- NRG standard analog sensors (200P Wind Direction Vane, 110S Temperature, BP20 Barometric Pressure, RH5X Relative Humidity, etc)
- Industry-standard pyranometers
- Built-in channels 13-15: 0 to 5 V Analog; 2.5 or 5 V excitation; no P-SCMs required
- Built-in channels 16-19: 0 to 5 V Analog; 5 or 12 V excitation; no P-SCMs required
- P-SCM Channels 20-26: signal range dependent on individual P-SCM card
- Sensor wiring
-
- Sensors connected to wiring panel
- Field wiring panel mounted in shelter box connected to logger via interconnect cable
- Ground stud connects to earth ground with includedwith ground cable
- Expansion slots
-
Seven (7) signal conditioning module slots accept analog P-SCMs
- Two (2) RS-485 serial communication ports on wiring panel
- Mounting
- Wiring panel mounts separately to shelter box back plate with four (4) Phillips 10-32 x 0.5 in. screws
- Tools required
-
- Screwdriver for wiring panel input terminals (included)
- 8mm (5/16 in.) wrench or nut driver for mounting screws and logger ground lug
- Operating temperature range
- -40 °C to 65 °C (-40 °F to 149 °F)
- Operating humidity range
- 0 to 100% RH non-condensing
- Weight
-
- Wiring Panel: .73 Kg (1.6 lbs)
- Interconnect Cable: .24 Kg (.52 lb)
- Dimensions
-
- Wiring Panel: 30 cm x 12 cm x 12 cm (11.8 in. x 4.7 in x 4.7 in)
- Interconnect Cable: 40.6 cm (16 in)
- Wiring panel
- Formed aluminum enclosure, zinc-plated screws and terminals
Product Support
Customer Service
+1 802-482-2255
Mon – Fri: 8:30am – 5:00pm Eastern Time (GMT-5)