NRG Systems

Data Logger Wiring Panel Kits

Connect sensors and protect your data logger from electrostatic discharge with an NRG wiring panel.

  SYMPHONIEPRO, 16-CHANNEL (#11178) SYMPHONIEPRO, 26-CHANNEL (#9294)
Description  
Instrument type 16 channel wiring panel for SymphoniePRO Data Logger 26 channel wiring panel for SymphoniePRO Data Logger
Applications Wind and solar resource assessment, power performance monitoring, and forecasting Wind and solar resource assessment, power performance monitoring, and forecasting
Instrument compatibility SymphoniePRO data logger SymphoniePRO data logger
Data Collection  
Channel Capacity
  • Eight (8) counter channels
  • Eight (8) analog channels: Five (5) built-in, Three (3) configurable with signal conditioning modules (P-SCMs)
  • Twelve (12) counter channels
  • Fourteen (14) analog channels: Seven (7) built-in, Seven (7) configurable with signal conditioning modules (P-SCMs)
  • Two (2) RS-485 communication channels, each full or half duplex with support for up to 6 devices
Counter Channels Sensor Compatibility Compatable with a wide array of industry-standard anemometers including:
  • Opto anemometers
  • Reed switch anemometers
  • Other frequency signals up to 2,500 Hz
Compatable with a wide array of industry-standard anemometers including:
  • Opto anemometers
  • Reed switch anemometers
  • Other frequency signals up to 2,500 Hz
Analog Channels Sensor Compatibility Compatible with a wide array of sensors including:
  • NRG standard analog sensors (200P Wind Direction Vane, 110S Temperature, BP20 Barometric Pressure, RH5X Relative Humidity, etc)
  • Industry-standard pyranometers
  • Three (3) Built-in channels: 0 to 5 V Analog; 2.5 or 5 V excitation; no P-SCMs required
  • Two (2) Built-in channels: 0 to 5 V Analog; 5 or 12 V excitation; no P-SCMs required
  • Three (3) P-SCM Channels: signal range dependent on individual P-SCM card
Compatible with a wide array of sensors including:
  • NRG standard analog sensors (200P Wind Direction Vane, 110S Temperature, BP20 Barometric Pressure, RH5X Relative Humidity, etc)
  • Industry-standard pyranometers
  • Built-in channels 13-15: 0 to 5 V Analog; 2.5 or 5 V excitation; no P-SCMs required
  • Built-in channels 16-19: 0 to 5 V Analog; 5 or 12 V excitation; no P-SCMs required
  • P-SCM Channels 20-26: signal range dependent on individual P-SCM card
Connections  
Sensor wiring
  • Sensors connect to wiring panel
  • Field wiring panel plugs directly into logger
  • Wiring panel ground stud connects to earth ground with included ground cable
  • Sensors connected to wiring panel
  • Field wiring panel mounted in shelter box connected to logger via interconnect cable
  • Ground stud connects to earth ground with includedwith ground cable
Expansion slots Three (3) Analog channels configurable with P-SCM signal conditioning modules Seven (7) signal conditioning module slots accept analog P-SCMs
  • Two (2) RS-485 serial communication ports on wiring panel
Installation  
Mounting Wiring panel mounts directly to Logger with two screws Wiring panel mounts separately to shelter box back plate with four (4) Phillips 10-32 x 0.5 in. screws
Tools required
  • Screwdriver for wiring panel input terminals (included)
  • 8mm (5/16 in.) wrench or nut driver for mounting screws and logger ground lug
  • Screwdriver for wiring panel input terminals (included)
  • 8mm (5/16 in.) wrench or nut driver for mounting screws and logger ground lug
Environmental  
Operating temperature range -40 °C to 65 °C (-40 °F to 149 °F) -40 °C to 65 °C (-40 °F to 149 °F)
Operating humidity range
  • 0 to 100% relative humidity non-condensing
  • IP65 ingress protection with proper installation in Symphonie shelter box enclosure
0 to 100% RH non-condensing
Physical  
Weight .15 Kg (.33 lb)
  • Wiring Panel: .73 Kg (1.6 lbs)
  • Interconnect Cable: .24 Kg (.52 lb)
Dimensions 11.4 cm x 7.6 cm x 5 cm (4.5 in. x 3 in. x 2 in.)
  • Wiring Panel: 30 cm x 12 cm x 12 cm (11.8 in. x 4.7 in x 4.7 in)
  • Interconnect Cable: 40.6 cm (16 in)
Materials  
Wiring panel
  • Black ABS enclosure
  • Zinc-plated screws and terminals
Formed aluminum enclosure, zinc-plated screws and terminals

NRG Systems • 110 Riggs Road • Hinesburg, Vermont 05461 • +1 802-482-2255 • info@nrgsystems.com