A 110S temperature sensor connected to a 9200-PLUS NRG Logger’s Extra Analog Channel is showing high readings such as 214

The 9200-Plus logger's extra analog channel is set up to read every 10mV of input as one count". The logger is measuring the voltage output of whatever sensor is connected. The ASCII data file will show counts, which could range from 0 to a max of 255 counts. The 110S sensor output will provide 10mV per each degree F of temperature with an offset of 123.5. Here is how to calculate your temperature: Degrees F=((counts x .01V)-1.235V)/.01 For example: ASCII data reading of 214 counts ((214 x .01V)-1.235V)/.01V = 90.5 degrees F.

 