Explanation: Symphonie hardware revision
The Symphonie system reports the hardware revision as follows:
XXX-YYY-ZZZ
where
XXX = the logger firmware revision
YYY = the MMC control and user interface firmware revision
ZZZ = the iPack firmware revision
Note: if the iPack firmware revision is reported as 000, the logger did not detect an iPack present at the time the rwd file was created. This could be a sign that the iPack battery has depleted, the iPack was removed or an external event has affected the logger which prevented it from detecting the iPack.
If you see the iPack revision change to 000 (in emailed data), it is suggested that the event log in SDR is checked.
In SDR, Site>View Event Log select site from list and click "OK".
Download Calibration Reports
Our Calibration Report Retriever Tool is a comprehensive database of reports for the following products:
NRG Anemometers
110S Temperature Sensor
200M Wind Vane
200P Wind Vane
BP20 Barometric Pressure Sensor
BP60 + BP60C Barometric Pressure Sensor
HybridMC Anemometer + Vane
HybridXT Anemometer + Vane
PVT1 PV Temperature Sensor
T60 + T60C Temperature Sensor
R1 Pyranometer
R2 Pyranometer
RH5X Relative Humidity Sensor
Thies First Class Advanced Anemometer
WindSensor P2546-OPR Anemometer
Tech Support
Whether you are troubleshooting in the field or learning how to install a product, we are here for you.