Connect sensors and protect your data logger from electrostatic discharge with an NRG wiring panel.

  • Data Logger Wiring Panel Kits

    SymphoniePRO 16-Channel Wiring Panel

  • SymphoniePRO 26-Channel Wiring Panel

  • SymphoniePRO 26-Channel Wiring Panel

  • SymphoniePLUS3 15-Channel Wiring Panel

  • Data Logger Wiring Panel Kits
  • Thumbnail for
  • Thumbnail for
  • Thumbnail for

Configuration Options

Our wiring panels are designed with the field user in mind. Dedicated terminals for every sensor wire and clear labeling help ensure mistake-free wiring. These input protection devices are required to connect digital and analog sensors to Symphonie® series data loggers. Each wiring panel features channel-by-channel surge protection to shield sensitive data logger circuitry from electrostatic discharge (ESD).

In the event of a lightning strike, the wiring panel will divert the energy to Earth Ground, protecting the data logger from damage. Severe ESD events may require replacement of the wiring panel to restore normal data logging operations.

We recommend carrying a spare wiring panel when performing site visits.

  SymphoniePRO, 16-Channel (#11178) SymphoniePRO, 26-Channel (#9294) SymphoniePLUS®3 (#5917)
Description  
Instrument type 16 channel wiring panel for SymphoniePRO Data Logger 26 channel wiring panel for SymphoniePRO Data Logger 15 channel wiring panel for SymphoniePLUS3 data logger
Applications Wind and solar resource assessment, power performance monitoring, and forecasting Wind and solar resource assessment, power performance monitoring, and forecasting
  • Wind resource assessment
  • Turbine power performance verification
Instrument compatibility SymphoniePRO data logger SymphoniePRO data logger SymphoniePLUS3 data logger
Data Collection  
Channel Capacity
  • Eight (8) counter channels
  • Eight (8) analog channels: Five (5) built-in, Three (3) configurable with signal conditioning modules (P-SCMs)
  • Twelve (12) counter channels
  • Fourteen (14) analog channels: Seven (7) built-in, Seven (7) configurable with signal conditioning modules (P-SCMs)
  • Two (2) RS-485 communication channels, each full or half duplex with support for up to 6 devices
  • Six (6) counter channels: Channels 1-3 and 13-15
  • Six (6) analog channels: Channels 7-12
    Channels 7-8 dedicated for NRG 200P Wind Direction Vane; Channels 9-12 use analog Signal Conditioning Modules (SCMs) to configure each channel for a particular sensor
  • Three (3) flex channels: Channels 4-6
    Analog or counter channel; accepts Signal Conditioning Modules (SCMs) to configure the channel for a particular sensor type
Counter Channels Sensor Compatibility Compatable with a wide array of industry-standard anemometers including:
  • Opto anemometers
  • Reed switch anemometers
  • Other frequency signals up to 2,500 Hz
Compatable with a wide array of industry-standard anemometers including:
  • Opto anemometers
  • Reed switch anemometers
  • Other frequency signals up to 2,500 Hz
Compatable with a wide array of industry-standard anemometers including:
  • Opto anemometers
  • Reed switch anemometers
  • Other frequency signals up to 2,500 Hz
Analog Channels Sensor Compatibility Compatible with a wide array of sensors including:
  • NRG standard analog sensors (200P Wind Direction Vane, 110S Temperature, BP20 Barometric Pressure, RH5X Relative Humidity, etc)
  • Industry-standard pyranometers
  • Three (3) Built-in channels: 0 to 5 V Analog; 2.5 or 5 V excitation; no P-SCMs required
  • Two (2) Built-in channels: 0 to 5 V Analog; 5 or 12 V excitation; no P-SCMs required
  • Three (3) P-SCM Channels: signal range dependent on individual P-SCM card
Compatible with a wide array of sensors including:
  • NRG standard analog sensors (200P Wind Direction Vane, 110S Temperature, BP20 Barometric Pressure, RH5X Relative Humidity, etc)
  • Industry-standard pyranometers
  • Built-in channels 13-15: 0 to 5 V Analog; 2.5 or 5 V excitation; no P-SCMs required
  • Built-in channels 16-19: 0 to 5 V Analog; 5 or 12 V excitation; no P-SCMs required
  • P-SCM Channels 20-26: signal range dependent on individual P-SCM card
  • NRG 200P Wind Direction Vane
  • NRG 110S Temperature Sensor
  • NRG BP20 Barometric Pressure Sensor (requires optional iPack power)
  • NRG RH5X Relative Humidity Sensor (requires optional iPack power)
Connections  
Sensor wiring
  • Sensors connect to wiring panel
  • Field wiring panel plugs directly into logger
  • Wiring panel ground stud connects to earth ground with included ground cable
  • Sensors connected to wiring panel
  • Field wiring panel mounted in shelter box connected to logger via interconnect cable
  • Ground stud connects to earth ground with includedwith ground cable
  • Sensors connected to field wiring panel
  • Field wiring panel plugs into logger
  • Ground stud connects to earth ground with included ground cable
Expansion slots Three (3) Analog channels configurable with P-SCM signal conditioning modules Seven (7) signal conditioning module slots accept analog P-SCMs
  • Two (2) RS-485 serial communication ports on wiring panel
  • Three (3) SCM slots accept analog or counter SCMs
  • Four (4) SCM slots accept only analog SCMs
Installation  
Mounting Wiring panel mounts directly to Logger with two screws Wiring panel mounts separately to shelter box back plate with four (4) Phillips 10-32 x 0.5 in. screws Wiring panel mounts directly to Logger
Tools required
  • Screwdriver for wiring panel input terminals (included)
  • 8mm (5/16 in.) wrench or nut driver for mounting screws and logger ground lug
  • Screwdriver for wiring panel input terminals (included)
  • 8mm (5/16 in.) wrench or nut driver for mounting screws and logger ground lug
  • Screwdriver for input terminals (included)
  • 8 mm (5/16 inch) wrench or nut driver for logger mounting screws and logger ground nuts
Environmental  
Operating temperature range -40 °C to 65 °C (-40 °F to 149 °F) -40 °C to 65 °C (-40 °F to 149 °F) -40 °C to 65 °C (-40 °F to 149 °F)
Operating humidity range 0 to 100% relative humidity non-condensing 0 to 100% relative humidity non-condensing 0 to 100% RH non-condensing
Physical  
Weight .15 Kg (.33 lb)
  • Wiring Panel: .73 Kg (1.6 lbs)
  • Interconnect Cable: .24 Kg (.52 lb)
.15 Kg (.33 lb)
Dimensions 11.4 cm x 7.6 cm x 5 cm (4.5 in. x 3 in. x 2 in.)
  • Wiring Panel: 30 cm x 12 cm x 12 cm (11.8 in. x 4.7 in x 4.7 in)
  • Interconnect Cable: 40.6 cm (16 in)
11.4 cm x 7.6 cm x 5 cm (4.5 in. x 3 in. x 2 in.)
Materials  
Wiring panel
  • Black ABS enclosure
  • Zinc-plated screws and terminals
Formed aluminum enclosure, zinc-plated screws and terminals Fiberglass-epoxy terminal board, sealed gold plated pins, zinc plated screws and terminals