Skip to navigation Skip to content
FAQs

Extending the cable for a 110S temperature sensor

The cable may be extended up to approximately 500 meters before the excitation signal will degrade and affect the operation of the temperature sensor. Cable should be 20 gauge and MUST be shielded. It is recommended that splices are carefully wrapped with high quality electrical tape or covered with heat shrink tubing appropriate for outdoor use. Connect shields really well to prevent electrical noise.

 

Download Calibration Reports

Our Calibration Report Retriever Tool is a comprehensive database of reports for the following products:

NRG Anemometers
110S Temperature Sensor
200M Wind Vane
200P Wind Vane
BP20 Barometric Pressure Sensor
BP60 + BP60C Barometric Pressure Sensor
HybridMC Anemometer + Vane
HybridXT Anemometer + Vane
PVT1 PV Temperature Sensor
T60 + T60C Temperature Sensor
R1 Pyranometer
RH5X Relative Humidity Sensor
Thies First Class Advanced Anemometer
WindSensor P2546-OPR Anemometer

Tech Support

Whether you are troubleshooting in the field or learning how to install a product, we are here for you.