9200-PLUS NRG Logger data collection
The logger counts incoming pulses for 2 seconds then converts this to a value. This value becomes one 'sample'. These samples are then used by the logger to determine 10 minute average, etc. The highest 2-second sample for the entire logging period is the peak gust. The values are stored as 'raw' counts inside the logger. The reading software scales the data for either metric (m/s) or English (mph) units as the data are read and files are created. The ASCII files show the gusts in the scaled units (m/s or mph) while the raw files keep the information in the raw format (pulses). The 9300 logger functions the same way but uses a 1 second sample.
Download Calibration Reports
Our Calibration Report Retriever Tool is a comprehensive database of reports for the following products:
NRG Anemometers
110S Temperature Sensor
200M Wind Vane
200P Wind Vane
BP20 Barometric Pressure Sensor
BP60 + BP60C Barometric Pressure Sensor
HybridMC Anemometer + Vane
HybridXT Anemometer + Vane
PVT1 PV Temperature Sensor
T60 + T60C Temperature Sensor
R1 Pyranometer
R2 Pyranometer
RH5X Relative Humidity Sensor
Thies First Class Advanced Anemometer
WindSensor P2546-OPR Anemometer
Tech Support
Whether you are troubleshooting in the field or learning how to install a product, we are here for you.