Skip to navigation Skip to content
Instruction Sheets

Technical Background Supporting Removal of the Lightning Ground Wire on TallTowers

Download pdf (25 KB)

Extensive testing and analysis conducted by NRG Systems, Inc and Lightning Technologies, Inc. concluded the NRG 60m XHD TallTower structural members and guy wires alone provide sufficient protection for the electronics and wiring against direct attachment lightning strikes to permit removal of the down-tower copper conductor. This write-up substantiates the removal of the down-tower copper conductor on all NRG XHD TallTowers.

The removal of the down-tower copper conductor does not impact the electrostatic discharge (ESD) protection of the electronics (sensors and Symphonie logger). No change has been made to the grounding system electronics, so their ESD protection is unaffected by removal of the down-tower conductor.

Download Calibration Reports

Our Calibration Report Retriever Tool is a comprehensive database of reports for the following products:

NRG Anemometers
110S Temperature Sensor
200M Wind Vane
200P Wind Vane
BP20 Barometric Pressure Sensor
BP60 + BP60C Barometric Pressure Sensor
HybridMC Anemometer + Vane
HybridXT Anemometer + Vane
PVT1 PV Temperature Sensor
T60 + T60C Temperature Sensor
R1 Pyranometer
RH5X Relative Humidity Sensor
Thies First Class Advanced Anemometer
WindSensor P2546-OPR Anemometer

Tech Support

Whether you are troubleshooting in the field or learning how to install a product, we are here for you.