The LOGR | Solar Data Logger is a versatile data logging solution, purpose-built for solar resource assessment and monitoring on utility-scale PV plants.
LOGR-SOLAR (#9432) | LOGR-SOLAR WITH CLOUD CONNECTIVITY (#19965) | |
---|---|---|
Description | ||
Instrument type | High utility data logger and real-time sensor interface | n/a |
Applications | Solar resource monitoring and solar resource assessment | n/a |
Data Collection | ||
Sampling interval | 1 Hz (IEC 61724-1 compliant) | n/a |
Averaging interval | 1-minute (IEC 61724-1 compliant) | n/a |
Real time clock | Internal battery-backed with time synchronization | n/a |
Storage medium | 8 GB microSD | n/a |
Maximum data storage | 90 days at 1 second and 365 days at 1 minute intervals | n/a |
Channel Capacity |
• Fourteen (14) analog channels (single-ended); Seven (7) differential • Twenty-four (24) serial channels via two (2) RS-485 communication ports • Two (2) PV Input channels (soiling measurement) • Ten (10) calculated channels plus dedicated soiling ratio calculation • Five (5) counter channels (two with sensor excitation) • Three (3) outputs to control 12 V loads or relays |
n/a |
Counter Channels Sensor Compatibility |
Compatible with a wide array of industry-standard anemometers, tipping bucket rain gauges, and other accumulator sensors (Refer to user manual for a complete list of supported sensors) |
n/a |
Analog Channels Sensor Compatibility |
Compatible with a wide array of sensors including, NRG meteorological sensor suite and pyranometers (Refer to user manual for a complete list of supported sensors) |
n/a |
Analog Measurement Accuracy |
Uncertainty (k=2):
|
n/a |
RS-485 Channels Sensor Compatibility |
Supports configurable Modbus RTU data acquisition. (Contact NRG to discuss support for additional model types or protocols) |
n/a |
Parameters recorded for each channel |
• Average • Standard deviation • Minimum/Maximum 1-sec sample • 3-second Wind gust Note: Statistics reported on each channel are dependent on measurement type |
n/a |
Data delivery |
• Real-time data delivery via Modbus registers (TCP via Ethernet or RTU via RS-485) • Scheduled delivery of historical data via FTP • On-demand transfer of historical data via internal web server to FTP |
n/a |
Security | Password-protected web server access | n/a |
Resolution | ||
Analog measurement resolution | 24-bit signed A/D conversion | n/a |
Software | ||
Type |
• Onboard web server for logger configuration and administration • Modbus Demo Client to test configured unit prior to connecting to SCADA |
n/a |
Configuration | ||
User interface |
• Web-based user interface via Ethernet connected computing device with web browser (such as Google Chrome) • Recessed reset button on front panel • Audible beeper for user feedback |
n/a |
Connections | ||
Sensor wiring |
Integrated wiring panel featuring removable terminal blocks: • Seven (7) dedicated analog sensor wiring ports • Four (4) dedicated RS-485 sensor wiring ports • Two (2) dedicated PV input ports • Five (5) Counter input ports • Three (3) Output ports • Enclosure ground lug connects to earth ground with included ground cable |
n/a |
Communication ports |
• Ethernet port for web browser, FTP, Modbus TCP (server) • RS-485 port for Modbus RTU (server) |
n/a |
Power requirements | ||
Batteries | Coin cell battery for clock backup | n/a |
External power input | 16 to 28 V DC | n/a |
External solar input | Contact NRG sales for accompanying backup power supply system options | n/a |
External power output |
• Constant 12 V source for powering analog sensors (50 mA per excitation port, 7 ports) • Constant 12 V source for powering modbus sensors (1000 mA shared by three COM-A ports and additional 1000mA to COM-B port) • Three (3) outputs to control external devices, 12 V DC (500 mA each, 1000 mA total maximum current) |
n/a |
Installation | ||
Mounting | 35 mm DIN Rail | n/a |
Tools required |
• Screwdriver for wiring input terminals (included) • Ethernet connected computing device with web browser (such as Google Chrome) |
n/a |
Environmental | ||
Operating temperature range | -40 °C to 65 °C (-40 °F to 149 °F) | n/a |
Operating humidity range |
• 0 to 100% relative humidity non-condensing • IP65 ingress protection with proper installation in NRG shelter box enclosure |
n/a |
Physical | ||
Dimensions | (190.5 x 101.6 x 101.6) mm | n/a |
Materials | ||
Enclosure | Formed aluminum enclosure | n/a |
Shipping | ||
Shipping weight | 0.91 kg (includes grounding wire and sensor plug set) | n/a |
NRG Systems • 110 Riggs Road • Hinesburg, Vermont 05461 • +1 802-482-2255 • info@nrgsystems.com