The NRG S1 Anemometer is a class 1 sensor that reduces measurement uncertainty and project cost for wind resource assessment and power performance testing.
| MEASNET CALIBRATED (#9405) | MEASNET CALIBRATED, DWG (#9416) | MEASNET CALIBRATED (2) (#14363) | MEASNET CALIBRATED, DWG (2) (#14365) | |
|---|---|---|---|---|
| Description | ||||
| Sensor type | 3-Cup Anemometer | 3-Cup Anemometer | 3-Cup Anemometer | 3-Cup Anemometer | 
| Applications | 
                      
  | 
                  
                    
                      
  | 
                  
                    
                      
  | 
                  
                    
                      
  | 
                  
                
| Sensor range | 0.638 m/s to 75 m/s (1.427 mph to 167.8 mph) | 0.638 m/s to 75 m/s (1.427 mph to 167.8 mph) | 0.638 m/s to 75 m/s (1.427 mph to 167.8 mph) | 0.638 m/s to 75 m/s (1.427 mph to 167.8 mph) | 
| Instrument compatibility | All NRG Systems Data Loggers | All NRG Systems Data Loggers | All NRG Systems Data Loggers | All NRG Systems Data Loggers | 
| Measurement range | 0.638 to 75 m/s | 0.6 to 75 m/s | 0.6 to 75 m/s | 0.6 to 75 m/s | 
| Output signal | ||||
| Signal type | 
                      Form: Square Wave  Frequency: 532.9 Hz @ 50 m/s (112 mph) Amplitude: Equal to supply voltage, max. 15 V  | 
                  
                    
                      Form: Square Wave  Frequency: 532.9 Hz @ 50 m/s (112 mph) Amplitude: Equal to supply voltage, max. 15 V  | 
                  
                    
                      Form: Square Wave  Frequency: 532.9 Hz @ 50 m/s (112 mph) Amplitude: Equal to supply voltage, max. 15 V  | 
                  
                    
                      Form: Square Wave  Frequency: 532.9 Hz @ 50 m/s (112 mph) Amplitude: Equal to supply voltage, max. 15 V  | 
                  
                
| Linearity | Refer to R^2 value on individual calibration report. | Refer to R^2 value on individual calibration report. | Refer to R^2 value on individual calibration report. | Refer to R^2 value on individual calibration report. | 
| Anemometer Transfer Function | 
                      
  | 
                  
                    
                      
  | 
                  
                    
                      
  | 
                  
                    
                      
  | 
                  
                
| Calibration | 
                      Each anemometer individually calibrated at SOH WE, Williston, VT USA. Calibration reports provided via electronic download.  | 
                  
                    
                      Each anemometer individually calibrated at DWG, Varel, DE. Calibration reports provided via electronic download.  | 
                  
                    
                      Each anemometer individually calibrated at SOH WE, Williston, VT USA. Calibration reports provided via electronic download.  | 
                  
                    
                      Each anemometer individually calibrated at DWG, Varel, DE. Calibration reports provided via electronic download.  | 
                  
                
| Output signal range | 0 Hz to 800 Hz | 0 Hz to 800 Hz | 0 Hz to 800 Hz | 0 Hz to 800 Hz | 
| Resolution | 0.046 m/s | 0.046 m/s | 0.046 m/s | 0.046 m/s | 
| Uncertainty | 
                      IEC 61400-12-1 Ed. 1 Classification
  | 
                  
                    
                      IEC 61400-12-1 Ed. 1 Classification
  | 
                  
                    
                      IEC 61400-12-1 Ed. 1 Classification
  | 
                  
                    
                      IEC 61400-12-1 Ed. 1 Classification
  | 
                  
                
| Response characteristics | ||||
| Threshold | 0.638 m/s (1.427 mph) per ASTM D 5096-02 | 0.638 m/s (1.427 mph) per ASTM D 5096-02 | 0.638 m/s (1.427 mph) per ASTM D 5096-02 | 0.638 m/s (1.427 mph) per ASTM D 5096-02 | 
| Distance constant (63% recovery) | 2.76 m (9.05 ft) per ASTM D 5096-02 | 2.76 m (9.05 ft) per ASTM D 5096-02 | 2.76 m (9.05 ft) per ASTM D 5096-02 | 2.76 m (9.05 ft) per ASTM D 5096-02 | 
| Moment of inertia | 
                      
  | 
                  
                    
                      
  | 
                  
                    
                      
  | 
                  
                    
                      
  | 
                  
                
| Power requirements | ||||
| Supply voltage | 5 to 28 VDC | 5 to 28 VDC | 5 to 28 VDC | 5 to 28 VDC | 
| Supply current | 
                      
  | 
                  
                    
                      
  | 
                  
                    
                      
  | 
                  
                    
                      
  | 
                  
                
| Installation | ||||
| Mounting | Onto a 25 mm (1") diameter mast with 2 set screws | Onto a 25 mm (1") diameter mast with 2 set screws | Onto a 25 mm (1") diameter mast with 2 set screws | Onto a 25 mm (1") diameter mast with 2 set screws | 
| Tools required | 2.5 mm Allen Key | 2.5 mm Allen Key | 2.5 mm Allen Key | 2.5 mm Allen Key | 
| Environmental | ||||
| Operating temperature range | -30 °C to 60 °C (-22 °F to 140 °F) | -30 °C to 60 °C (-22 °F to 140 °F) | -30 °C to 60 °C (-22 °F to 140 °F) | -30 °C to 60 °C (-22 °F to 140 °F) | 
| Operating humidity range | 0 to 100% RH | 0 to 100% RH | 0 to 100% RH | 0 to 100% RH | 
| Lifespan | > 2 years at most sites | > 2 years at most sites | > 2 years at most sites | > 2 years at most sites | 
| Other | 
                      
  | 
                  
                    
                      
  | 
                  
                    
                      
  | 
                  
                    
                      
  | 
                  
                
| Physical | ||||
| Connections | M12 Connector | M12 Connector | M12 Connector | M12 Connector | 
| Cable length | Various available | Various available | Various available | Various available | 
| Weight | Sensor weight = 190 grams (0.42 lbs) | Sensor weight = 190 grams (0.42 lbs) | Sensor weight = 190 grams (0.42 lbs) | Sensor weight = 190 grams (0.42 lbs) | 
| Dimensions | 
                      
  | 
                  
                    
                      
  | 
                  
                    
                      
  | 
                  
                    
                      
  | 
                  
                
| Materials | ||||
| Cups | One piece injection-molded black polycarbonate | One piece injection-molded black polycarbonate | One piece injection-molded black polycarbonate | One piece injection-molded black polycarbonate | 
| Body | Anodized Aluminium | Anodized Aluminium | Anodized Aluminium | Anodized Aluminium | 
| Shaft | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | 
| Bearing | Ball Bearings | Ball Bearings | Ball Bearings | Ball Bearings | 
| Signal generator | Optical Switch | Optical Switch | Optical Switch | Optical Switch | 
| Shipping | ||||
| Shipping weight | 
                      1 sensor-per-box Dimensional Weight = 8.0 lbs (3.6 kg)  | 
                  
                    
                      1 sensor-per-box Dimensional Weight = 8.0 lbs (3.6 kg)  | 
                  
                    
                      2 sensors-per-box Dimensional Weight = 11.0 lbs (5.0 kg)  | 
                  
                    
                      2 sensors-per-box Dimensional Weight = 11.0 lbs (5.0 kg)  | 
                  
                
| Shipping volume | 12" x 10" x 9" (30.5 cm x 25.4 cm x 22.9 cm) | 12" x 10" x 9" (30.5 cm x 25.4 cm x 22.9 cm) | 13" x 11" x 10" (33.0 cm x 27.9 cm x 25.4 cm) | 13" x 11" x 10" (33.0 cm x 27.9 cm x 25.4 cm) | 
NRG Systems • 110 Riggs Road • Hinesburg, Vermont 05461 • +1 802-482-2255 • info@nrgsystems.com