Convert the 40C Anemometer from AC sine wave to square wave.
INTERFACE 40C TO LOGIC LEVEL, SPEED AMP #892E (#2041) | |
---|---|
Description | |
Sensor type |
|
Applications |
|
Sensor compatibility |
|
Input signal | |
Signal type (sensor output) | low level AC sine wave |
Signal range (sensor output) | 0 Hz to 200 Hz |
Output signal | |
Signal type |
|
Transfer function | output signal follows input frequency |
Recommended load resistance | 1 kΩ minimum (5 mA load current maximum) |
Output signal range | equal to supply voltage |
Response characteristics | |
Threshold | 80 mV peak-to-peak minimum input signal |
Power requirements | |
Supply voltage |
|
Supply current | 15 µA |
Installation | |
Mounting | mating socket mounts to 35mm (type O) DIN rail or with screws to any flat surface |
Tools required | #1 Phillips (+) or flat blade (-) screwdriver for terminals |
Accessories | NRG #40 Maximum Anemometer, Item No. 1899 |
Wiring |
|
Environmental | |
Operating temperature range | -40 °C to 70 °C (-40 °F to 150 °F) |
Operating humidity range | 0 % to 95 % RH (non condensing) |
Physical | |
Connections | octal plug, mating socket with screw terminals included |
Weight | 75 g (0.17 pound) |
Dimensions |
|
Materials | |
Enclosure | plastic housing with octal plug base |
Terminals | octal plug, mating socket with screw terminals included |
Shipping | |
Shipping weight | 0.26 |
Shipping volume | 0.022 |
NRG Systems • 110 Riggs Road • Hinesburg, Vermont 05461 • +1 802-482-2255 • info@nrgsystems.com