Symphonie® iPACKACCESS

Integrate real-time meteorological data into your SCADA (Supervisory Control and Data Acquisition) system with the iPackACCESS communications module.

 
Description
Accessory type SCADA communications + power module for Symphonie series data loggers Communications + power module for SymphoniePRO data loggers n/a n/a
Applications Delivery of real-time (1 Hz sample) and statistical meteorological data for resource assessment, power performance testing and/or long-term monitoring, and forecasting Delivery of real-time (1 Hz sample) and statistical meteorological data for resource assessment, power performance testing and/or long-term monitoring, and/or forecasting. n/a n/a
Instrument compatibility SymphoniePRO and SymphoniePLUS3 data loggers SymphoniePRO data loggers n/a n/a
Functions
  • Delivery of meteorological data via Modbus TCP server, email, and/or MetLink* available over Ethernet
  • Supports up to 4 simultaneous Modbus TCP connections
  • Supports remote configuration and firmware updates to data logger and iPackACCESS via MetLink*
  • Automatic synchronization of data logger's real-time clock via GPS and/or internet time server*
  • Automatic download of logged data via email

    *Functionality enhanced by and/or exclusively available via SymphoniePRO
  • Delivery of meteorological data via:
  • Modbus TCP server, email, and/or MetLink* available over Ethernet
  • LTE-TDD cellular modem
  • Supports up to 4 simultaneous Modbus TCP/MetLink connections
  • Supports remote configuration and firmware updates to data logger and iPackACCESS via MetLink*
  • Automatic synchronization of data logger's real-time clock via GPS and/or internet time (NTP) server*
  • Automatic download of logged data via email

    *Functionality enhanced by and/or exclusively available via Ethernet interface
n/a n/a
Data Collection
Software Configuration via data logger desktop software on Windows PC (SymphoniePRO Desktop Application or Symphonie Data Retriever (SDR)) Configuration via data logger desktop software on Windows PC (SymphoniePRO Desktop Application (SPD)) n/a n/a
Data delivery
  • Data available via Modbus TCP server:
    - Real-time, 1 Hz sample data from all channels
    - Statistical values at user-selected time interval configured in the data logger (1, 2, 5, 10, 15, 30, and 60 minutes)*
  • Raw logger data files available by email and/or MetLink via SCADA network?s internet connection, or via logger USB connection or SD card*

    *Functionality enhanced by and/or exclusively available via SymphoniePRO
  • Data available via Modbus TCP server:
  • Real-time, 1 Hz sample data from all channels
  • Statistical values at user-selected time interval configured in the data logger (1, 2, 5, 10, 15, 30, and 60 minutes)*
  • Raw logger data files available:
  • by email and/or MetLink via Ethernet interface (SCADA network connection)
  • by email only via cellular modem
  • locally via logger USB connection or SD card
n/a n/a
Configuration
User interface
  • Status reporting via data logger user interface
  • Configuration via data logger desktop software on Windows PC (SymphoniePRO Desktop Application or Symphonie Data Retriever (SDR))
  • Status reporting via data logger user interface
  • Configuration via data logger desktop software on Windows PC (SymphoniePRO Desktop Application (SPD))
n/a n/a
Configurable parameters
  • Modbus secure client list to prevent unauthorized access by limiting the acceptable IP addresses for incoming connections (up to 10 allowable addresses)
  • Network configuration parameters
  • DHCP capable
  • Modbus secure client list to prevent unauthorized access by limiting the acceptable IP addresses for incoming connections (up to 10 allowable addresses)
  • Network configuration parameters
  • DHCP capable
n/a n/a
Connections
Communication ports
  • Weatherproof Ethernet connector (RJ45) for connection to SCADA system
  • DB25 interface for connection to data logger
  • QMA (f) connector for GPS antenna
  • Weatherproof Ethernet connector (RJ45) for connection to SCADA system
  • DB25 connector for interface to data logger
  • QMA (f) connector for GPS antenna
  • SMA (f) connector for cellular antenna
n/a n/a
Power requirements
Batteries Two (2) built-in 12 V Sealed Lead-Acid (SLA) batteries with 2200 mAh rating each (4400 mAh total) Two (2) built-in 12 V Sealed Lead-Acid (SLA) batteries with 2200 mAh rating each (4400 mAh total) n/a n/a
External power input
  • Charging circuit input (open circuit voltage 15 to 28 V)
  • External battery input (12 to 14 V)
  • Charging circuit input (open circuit voltage 15 to 28 V)
  • External battery input (12 to 14 V)
n/a n/a
External power output Smart-switched 12 V DC output from internal SLA batteries (~4400 mAh)*

*Functionality enhanced by and/or exclusively available via SymphoniePRO
Smart-switched 12 V DC output from internal SLA batteries (~4400 mAh) n/a n/a
Installation
Mounting iPackACCESS attaches to back of SymphoniePRO or SymphoniePLUS3 data logger with (4) long logger mounting screws iPackACCESS attaches to back of SymphoniePRO data logger with (4) long logger mounting screws n/a n/a
Accessories Weatherproof Ethernet cable boot and GPS antenna (both included) Weatherproof Ethernet cable boot, GPS antenna, and cellular antenna (included) n/a n/a
Physical
Connections
  • Two (2) screw terminals for solar PV panel or external power supply input
  • Two (2) screw terminals for external battery
  • Two (2) screw terminals for 12 V power output
  • One (1) screw terminal for earth ground, pre-wired for connection to data logger earth ground stud
  • Two (2) screw terminals for solar PV panel or external power supply input
  • Two (2) screw terminals for external battery
  • Two (2) screw terminals for 12 V power output
  • One (1) screw terminal for earth ground, pre-wired for connection to data logger earth ground stud
n/a n/a
Dimensions 165 x 222 x 102 mm (6.5 x 8.75 x 4.0 inches) 165 x 222 x 102 mm (6.5 x 8.75 x 4.0 inches) n/a n/a
Materials
Enclosure
  • Weather-proof polycarbonate plastic
  • IP65 Rated
  • Weather-proof polycarbonate plastic
  • IP65 Rated
n/a n/a
System requirements
Computer
  • Windows PC with SymphoniePRO Desktop Application (for SymphoniePRO) or Symphonie Data Retriever (SDR; for SymphoniePLUS3) required for configuration
  • Modbus Demo Client utility for network connection testing and troubleshooting
  • Windows PC with SymphoniePRO Desktop Application (SPD) required for configuration
  • Modbus Demo Client software utility for network connection testing and troubleshooting
n/a n/a
Operating system
  • SymphoniePRO Desktop Application requires Windows XP or higher
  • Symphonie Data Retriever (SDR) requires Windows 95 or higher
  • SymphoniePRO Desktop Application requires Windows 7 or higher
n/a n/a
Related hardware
  • SymphoniePRO Data Logger (item 8547)
    - USB Cable | 15 FT, A to B Type (item 8633)
  • SymphoniePLUS3 Data Logger (item 5504)
    - iPack Programming Kit (item 3368)
  • Universal iPack Charger (item 3615)
  • SymphoniePRO Data Logger (item 8547)
  • USB Cable | 15 FT, A to B Type (item 8633)
  • Universal iPack Charger (item 3615)
n/a n/a

NRG Systems • 110 Riggs Road • Hinesburg, Vermont 05461 • +1 802-482-2255 • info@nrgsystems.com