Symphonie® iPACKACCESS

Integrate real-time meteorological data into your SCADA (Supervisory Control and Data Acquisition) system with the iPackACCESS communications module.

  SYMPHONIE IPACKACCESS (#7169) LTE-G AT&T (#16691) 4G LTE-TDD - SOLAR (#9406) LTE-G GLOBAL (#16693)
Description
Accessory type SCADA communications + power module for Symphonie series data loggers n/a Communications + power module for SymphoniePRO data loggers n/a
Applications Delivery of real-time (1 Hz sample) and statistical meteorological data for resource assessment, power performance testing and/or long-term monitoring, and forecasting n/a Delivery of real-time (1 Hz sample) and statistical meteorological data for resource assessment, power performance testing and/or long-term monitoring, and/or forecasting. n/a
Instrument compatibility SymphoniePRO and SymphoniePLUS3 data loggers n/a SymphoniePRO data loggers n/a
Functions
  • Delivery of meteorological data via Modbus TCP server, email, and/or MetLink* available over Ethernet
  • Supports up to 4 simultaneous Modbus TCP connections
  • Supports remote configuration and firmware updates to data logger and iPackACCESS via MetLink*
  • Automatic synchronization of data logger's real-time clock via GPS and/or internet time server*
  • Automatic download of logged data via email

    *Functionality enhanced by and/or exclusively available via SymphoniePRO
n/a
  • Delivery of meteorological data via:
  • Modbus TCP server, email, and/or MetLink* available over Ethernet
  • LTE-TDD cellular modem
  • Supports up to 4 simultaneous Modbus TCP/MetLink connections
  • Supports remote configuration and firmware updates to data logger and iPackACCESS via MetLink*
  • Automatic synchronization of data logger's real-time clock via GPS and/or internet time (NTP) server*
  • Automatic download of logged data via email

    *Functionality enhanced by and/or exclusively available via Ethernet interface
n/a
Data Collection
Software Configuration via data logger desktop software on Windows PC (SymphoniePRO Desktop Application or Symphonie Data Retriever (SDR)) n/a Configuration via data logger desktop software on Windows PC (SymphoniePRO Desktop Application (SPD)) n/a
Data delivery
  • Data available via Modbus TCP server:
    - Real-time, 1 Hz sample data from all channels
    - Statistical values at user-selected time interval configured in the data logger (1, 2, 5, 10, 15, 30, and 60 minutes)*
  • Raw logger data files available by email and/or MetLink via SCADA network?s internet connection, or via logger USB connection or SD card*

    *Functionality enhanced by and/or exclusively available via SymphoniePRO
n/a
  • Data available via Modbus TCP server:
  • Real-time, 1 Hz sample data from all channels
  • Statistical values at user-selected time interval configured in the data logger (1, 2, 5, 10, 15, 30, and 60 minutes)*
  • Raw logger data files available:
  • by email and/or MetLink via Ethernet interface (SCADA network connection)
  • by email only via cellular modem
  • locally via logger USB connection or SD card
n/a
Configuration
User interface
  • Status reporting via data logger user interface
  • Configuration via data logger desktop software on Windows PC (SymphoniePRO Desktop Application or Symphonie Data Retriever (SDR))
n/a
  • Status reporting via data logger user interface
  • Configuration via data logger desktop software on Windows PC (SymphoniePRO Desktop Application (SPD))
n/a
Configurable parameters
  • Modbus secure client list to prevent unauthorized access by limiting the acceptable IP addresses for incoming connections (up to 10 allowable addresses)
  • Network configuration parameters
  • DHCP capable
n/a
  • Modbus secure client list to prevent unauthorized access by limiting the acceptable IP addresses for incoming connections (up to 10 allowable addresses)
  • Network configuration parameters
  • DHCP capable
n/a
Connections
Communication ports
  • Weatherproof Ethernet connector (RJ45) for connection to SCADA system
  • DB25 interface for connection to data logger
  • QMA (f) connector for GPS antenna
n/a
  • Weatherproof Ethernet connector (RJ45) for connection to SCADA system
  • DB25 connector for interface to data logger
  • QMA (f) connector for GPS antenna
  • SMA (f) connector for cellular antenna
n/a
Power requirements
Batteries Two (2) built-in 12 V Sealed Lead-Acid (SLA) batteries with 2200 mAh rating each (4400 mAh total) n/a Two (2) built-in 12 V Sealed Lead-Acid (SLA) batteries with 2200 mAh rating each (4400 mAh total) n/a
External power input
  • Charging circuit input (open circuit voltage 15 to 28 V)
  • External battery input (12 to 14 V)
n/a
  • Charging circuit input (open circuit voltage 15 to 28 V)
  • External battery input (12 to 14 V)
n/a
External power output Smart-switched 12 V DC output from internal SLA batteries (~4400 mAh)*

*Functionality enhanced by and/or exclusively available via SymphoniePRO
n/a Smart-switched 12 V DC output from internal SLA batteries (~4400 mAh) n/a
Installation
Mounting iPackACCESS attaches to back of SymphoniePRO or SymphoniePLUS3 data logger with (4) long logger mounting screws n/a iPackACCESS attaches to back of SymphoniePRO data logger with (4) long logger mounting screws n/a
Accessories Weatherproof Ethernet cable boot and GPS antenna (both included) n/a Weatherproof Ethernet cable boot, GPS antenna, and cellular antenna (included) n/a
Physical
Connections
  • Two (2) screw terminals for solar PV panel or external power supply input
  • Two (2) screw terminals for external battery
  • Two (2) screw terminals for 12 V power output
  • One (1) screw terminal for earth ground, pre-wired for connection to data logger earth ground stud
n/a
  • Two (2) screw terminals for solar PV panel or external power supply input
  • Two (2) screw terminals for external battery
  • Two (2) screw terminals for 12 V power output
  • One (1) screw terminal for earth ground, pre-wired for connection to data logger earth ground stud
n/a
Dimensions 165 x 222 x 102 mm (6.5 x 8.75 x 4.0 inches) n/a 165 x 222 x 102 mm (6.5 x 8.75 x 4.0 inches) n/a
Materials
Enclosure
  • Weather-proof polycarbonate plastic
  • IP65 Rated
n/a
  • Weather-proof polycarbonate plastic
  • IP65 Rated
n/a
System requirements
Computer
  • Windows PC with SymphoniePRO Desktop Application (for SymphoniePRO) or Symphonie Data Retriever (SDR; for SymphoniePLUS3) required for configuration
  • Modbus Demo Client utility for network connection testing and troubleshooting
n/a
  • Windows PC with SymphoniePRO Desktop Application (SPD) required for configuration
  • Modbus Demo Client software utility for network connection testing and troubleshooting
n/a
Operating system
  • SymphoniePRO Desktop Application requires Windows XP or higher
  • Symphonie Data Retriever (SDR) requires Windows 95 or higher
n/a
  • SymphoniePRO Desktop Application requires Windows 7 or higher
n/a
Related hardware
  • SymphoniePRO Data Logger (item 8547)
    - USB Cable | 15 FT, A to B Type (item 8633)
  • SymphoniePLUS3 Data Logger (item 5504)
    - iPack Programming Kit (item 3368)
  • Universal iPack Charger (item 3615)
n/a
  • SymphoniePRO Data Logger (item 8547)
  • USB Cable | 15 FT, A to B Type (item 8633)
  • Universal iPack Charger (item 3615)
n/a

NRG Systems • 110 Riggs Road • Hinesburg, Vermont 05461 • +1 802-482-2255 • info@nrgsystems.com