Configuration Options

Symphonie SCMs are compatible with Symphonie series data loggers (the SymphoniePLUS®3 Data Logger and older). For the SymphoniePRO® Data Logger, we offer a new set of signal conditioning modules called P-SCMs. Consult our sales or tech services team for the appropriate P-SCMs for your desired sensor configuration.

These Symphonie SCMs install into one of the SymphoniePLUS3's three flex channel SCM slots or one of the four analog channel SCM slots. Flex channels can accommodate sensors that have analog or digital signals, while analog channels can only be used with sensors that have an analog output. Once installed, the input channel is configured to accommodate sensor outputs within the card’s stated signal range.

 
Item #
Symphonie® SCM Card Description
SymphoniePLUS3 Channel Compatibility*
Example Sensor Compatibility
Pyranometer SCMs 6646 Hukseflux LP02 or Kipp & Zonen CMP3 4-6, 9-12
  • Hukseflux LP02 Pyranometer
  • Hukseflux SR03 Pyranometer
  • Hukseflux SR11 Pyranometer
  • Hukseflux SR12 Pyranometer
  • Hukseflux SR20 Pyranometer
  • Kipp & Zonen CMP3
  • Kipp & Zonen CMP6
6946 Thermopile, Kipp & Zonen CMP11 4-6, 9-12
  • Kipp & Zonen CMP11
  • Kipp & Zonen CMP21
3154 Li-Cor LI-200R 4-6, 9-12
  • Li-Cor LI-200R Pyranometer
7759 SPN1 - Sushine Duration 4-6, 9-12
  • Delta-T SPN1 Sunshine Pyranometer
7757 SPN1 - GHI, DIF 4-6, 9-12
  • Delta-T SPN1 Sunshine Pyranometer
Anemometer SCMs 3148 Coil Anemometer 4-6
  • 40C Anemometer
  • RNRG Class 1 Anemometer
  • WindSensor P2546C-OPR Anemometer
3151 Digital Anemometer 4-6
  • 40H Anemometer
  • WindSensor P2546A-OPR Anemometer
3746 RMY Wind Monitor, Anemometer 4-6
  • RM Young Wind Monitor
3745 RMY Vertical Prop 4-6
  • RM Young 27106-T Vertical Anemometer
Other SCMs 3152 200P Wind Vane 4-6, 9-12
  • 200P Wind Direction Vane
3153 110S 4-6, 9-12
  • 110S Temperature Sensor
3156 RH5X 4-6, 9-12
  • RH5X Relative Humidity Sensor
3155 BP20 4-6, 9-12
  • BP20 Barometric Pressure Sensor
3149 Rain Gauge 4-6, 9-12
  • Rain Gauge - Tipping Bucket
7758 Analog 0-1V Signal 4-6, 9-12
  • 3rd party sensors with 0 to 1 V output signal
3691 Analog Voltmeter 4-6, 9-12
  • Battery bank monitoring
  • 3rd party voltage output sensors
3585 iPack Voltmeter 4-6, 9-12
  • Provides logging of Symphonie iPack 12 V battery

*4-6 are flex channels. 9-12 are analog channels.